Do you have any questions about our products? Our experts will be glad to assist you! Just give us a call +32 (0)380 868 81

Product Comparison for 2 products

 Forward
Article
Technical Data
Cable length:
Side 1
Tightening torque:
Mounting method:
Family construction form:
Thread:
suitable for corrugated tube (internal Ø):
Coding:
Material:
Width across flats:
Degree of protection (EN IEC 60529):
Side 2
Tightening torque:
Mounting method:
Family construction form:
Thread:
suitable for corrugated tube (internal Ø):
Coding:
Material:
Width across flats:
Degree of protection (EN IEC 60529):
Electrical data | Supply
Operating voltage AC max.:
Operating voltage DC max.:
Operating voltage AC (UL-listed):
Operating voltage DC (UL-listed):
Current operating per contact max.:
Installation | Connection
Mounting set:
Device protection | Electrical
Additional condition protection degree:
Pollution Degree:
Rated surge voltage:
Material group (IEC 60664-1):
Mechanical data | Material data
Coating locking:
Coating of fitting:
Locking material:
Material screw connection:
Mechanical data | Mounting data
Mounting method:
Environmental characteristics | Climatic
Operating temperature min.:
Operating temperature max.:
Additional condition temperature range:
Important installation notes
Note on strain relief:
Note on bending radius:
Conformity
Product standard:
Cable data
General data | Cable
STOOW style jacket:
Cable identification:
Cable Type:
Printing color of wire insulation:
Printing spacing of wire insulation:
Jacket Color:
Type of Certificate:
Structure | Cable
Stranding factor max. (type 5):
Amount stranding:
Stranding:
Stranding factor min.:
Stranding factor max.:
Amount stranding (type 2):
Stranding (type 2):
Stranding factor min. (type 2):
Stranding factor max. (type 2):
Amount stranding (type 3):
Stranding (type 3):
Stranding factor min. (type 3):
Stranding factor max. (type 3):
Cable shielding (type):
Cable shielding (coverage):
Pair shielding (type):
Banding:
Filler:
Drain wire (type):
Drain wire (cross-section):
wire arrangement:
Mechanical data | Cable
Traversing distance (C-track):
Travel speed (C-track):
Cable length max.:
Cable weigth:
Material jacket:
Shore hardness jacket:
Freedom from ingredients (jacket):
Outer-diameter (jacket):
Tolerance outer diameter (sheath):
Material inner jacket:
Color (inner jacket):
Material wire insulation:
Amount wires:
Outer diameter insulation :
Outer diameter tolerance core insulation:
Shore hardness wire insulation:
Material properties wire insulation:
Ingredient freeness wire insulation:
Printing color of wire insulation:
Printing spacing of wire insulation:
Resistances wire insulation:
Amount strands (wire):
Diameter of single wires:
Conductor crosssection (wire):
Drain wire (cross-section):
Material conductor wire:
Conductor type (wire):
Electrical function wire:
Material wire insulation (Data):
Outer diameter wire insulation (Data):
Tolerance outer diameter wire insulation (data):
Shore hardness wire insulation (Data) :
Material properties wire insulation (Data):
Ingredient freeness wire insulation (Data):
Resistances wire insulation (Data):
Printing color wire insulation (data):
Printing spacing wire insulation (Data):
Amount wires (Data):
Amount strands wire (Data):
Diameter of single wires (Data):
Conductor crosssection wire (Data):
Material conductor wire (Data):
Wire conductor type (Data):
Electrical function wire (data):
Material wire insulation (Power):
Outer diameter wire insulation (Power):
Tolerance outer diameter wire insulation (Power):
Shore hardness wire insulation (Power):
Material properties wire insulation (Power):
Ingredient freeness wire insulation (Power):
Resistances wire insulation (Power):
Printing colour wire insulation (Power):
Printing spacing wire insulation (Power):
Amount strands wire (Power):
Diameter of single wires (Power):
Wire conductor cross section (Power):
Material conductor wire (Power):
Conductor type wire (Power):
Electrical function wire (Power):
Electrical data | Cable
Loop resistance:
Nominal voltage AC max.:
Max. rated voltage (conductor - conductor):
Max. rated voltage (conductor - ground):
Current load capacity (standard):
Current load capacity min. wire:
Current load capacity min. Wire (Data):
Electrical function wire:
Electrical function wire (data):
Characteristic impedance:
Electrical resistance line constant wire:
Electrical resistance coating wire (Power):
Electrical resistance coating wire (Data):
AC withstand voltage (wire - wire):
Electric inductivity line constant:
Electric capacitance:
Electrical capacity line constant (wire - wire):
Electrical capacity line constant (wire - shield):
Power frequency withstand voltage (wire - jacket):
AC withstand voltage (wire - shield):
Transmission frequency range:
Temperature range | Cable
Min. operating temperature (static):
Max. operating temperature (fixed):
Operating temperature min. (dynamic):
Operating temperature max. (dynamic):
Storage temperature min.:
Storage temperature max.:
Resistances | Cable
Hydrolysis resistance:
Ozone resistance:
Seewater resistance:
Acid and alkali resistance:
UV resistance:
Flame resistance:
chemical resistance:
Gasoline resistance:
Oil resistance:
Installation | Cable
Bending radius (installation):
Bending radius (fixed):
Bending radius (dynamic):
Travel speed (C-track):
No. of torsion cycles:
Torsion stress:
Torsion speed:
Classifications
ECLASS-6.0:
ECLASS-6.1:
ECLASS-7.0:
ECLASS-8.0:
ECLASS-9.0:
ECLASS-10.1:
ECLASS-11.1:
ECLASS-12.0:
ETIM-5.0:
Commercial data
customs tariff number:
Packaging unit:
GTIN:
Approvals
Certificates
Certificate
Certificate
Certificate
Certificate
Certificate
Certificate
Move
M12 male 0° / M12 female 90° A-cod. M12 male 0° / M12 female 90° A-cod.
PUR 5x0.34 ye UL/CSA 3m
Weight: 0.168 kg
Art.No.: 7000-40141-0250300

not available
Move
M12 male 0° / M12 female 90° A-cod. M12 male 0° / M12 female 90° A-cod.
PUR 5x0.34 ye UL/CSA+drag ch. 3m
Weight: 0.143 kg
Art.No.: 7000-40141-0350300

Available
3 m
3 m
0,6 Nm
0,6 Nm
inserted, screwed
inserted, screwed
M12
M12
M12 x 1
M12 x 1
10 mm
10 mm
A
A
PUR
PUR
SW13
SW13
IP65, IP66K, IP67
IP65, IP66K, IP67
0,6 Nm
0,6 Nm
inserted, screwed
inserted, screwed
M12
M12
M12 x 1
M12 x 1
10 mm
10 mm
A
A
PUR
PUR
SW13
SW13
IP65, IP66K, IP67
IP65, IP66K, IP67
125 V
125 V
125 V
125 V
30 V
30 V
30 V
30 V
4 A
4 A
M12 x 1
M12 x 1
inserted, screwed
inserted, screwed
3
3
1,5 kV
1,5 kV
I
I
Nickeled
Nickeled
nickel plated
nickel plated
Zinc die-casting
Zinc die-casting
Zinc die-casting
Zinc die-casting
inserted, screwed, Shaking protection
inserted, screwed, Shaking protection
-25 °C
-25 °C
85 °C
85 °C
depending on cable quality
depending on cable quality
-
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
-
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
DIN EN 61076-2-101 (M12)
DIN EN 61076-2-101 (M12)
-
-
834
035
-
3
-
-
-
-
blue
yellow
cURus
cURus
-
-
1
1
2 wires twisted
5 wires around Core filler twisted
-
-
-
-
1
-
2 Stranded joints twisted
-
-
-
-
-
-
-
-
-
-
-
-
-
copper braid, tinned
-
65 %
-
-
-
Foil
-
-
yes
-
-
22 AWG
-
(white, blue), (black, red)
brown, black, blue, white, green-yellow
5 m
10 m @ 25 °C | horizontal
-
-
-
-
63,12 g/m
41,8 g/m
PUR
PUR
90 ± 5 Shore A
90 ± 5 Shore A
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
6,9 mm
4,8 mm
± 5 %
± 5 %
-
-
-
-
PE
PP
2
5
2,1 mm
1,25 mm
± 5 %
± 5 %
64 ± 5 Shore D
70 ± 5 Shore D
-
-
lead-free, CFC-free, halogen-free
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
-
-
-
-
-
-
19
42
24 AWG
0,1 mm
24 AWG
0,34 mm²
22 AWG
-
copper stranded wire, tinned
Stranded copper wire, bare
-
strand class 6
Data
-
PE
-
1,5 mm
-
± 53 %
-
-
-
-
-
lead-free, CFC-free, halogen-free
-
-
-
-
-
-
-
2
-
19
-
22 AWG
-
22 AWG
-
copper stranded wire, tinned
-
-
-
Power
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
300 V
300 V
-
-
-
-
to DIN VDE 0298-4
to DIN VDE 0298-4
4,5 A
4,5 A
6 A
-
Data
-
Power
-
120 Ω ± 10 % @ 1 MHz
-
78 Ω/km
57 Ω/km @ 20 °C
-
-
54 Ω/km
-
2 kV @ 60 s
2,5 kV @ 60 s
-
-
40000 pF/km
-
-
-
-
-
-
2,5 kV @ 60 s
2 kV @ 60 s
-
-
-
-40 °C
-40 °C
80 °C
80 °C / 90 °C @ 10000 h Operation
-30 °C
-25 °C
70 °C
80 °C / 90 °C @ 10000 h Operation
-
-
-
-
-
-
-
-
-
-
-
-
-
-
UL 1581 § 1100 FT2 | UL 1581 § 1090 | IEC 60332-2-2
UL 1581 § 1100 FT2 | IEC 60332-2-2 | UL 1581 § 1090
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing | DIN EN 60811-404
DIN EN 60811-404 | Good, application-related testing
x Outer diameter
-
6 x Outer diameter
5 x Outer diameter
10 x Outer diameter
10 x Outer diameter
-
10 Mio. @ 25 °C
2 Mio.
2 Mio.
± 30 °/m
± 180 °/m
35 cycles/min
35 cycles/min
27279218
27279218
27279218
-
27279218
27279218
27279218
27279218
27060311
27060311
27060311
27060311
27060311
27060311
27060311
27060311
EC001855
EC001855
85444290
85444290
1
1
4048879337212
4048879177061
* plus VAT, plus shipping