Article |
|
Technical Data
|
Side 1 |
Family construction form:
|
Coding:
|
Material contact:
|
Electrical data | Supply |
Operating voltage AC max.:
|
Operating voltage DC max.:
|
Current operating per contact max.:
|
Installation |
Connection cross section max.:
|
AWG number max.:
|
Installation | Connection |
Connection:
|
Tightening torque:
|
Mounting set:
|
Width across flats:
|
Mating cycles min.:
|
Device protection | Electrical |
Degree of protection (EN IEC 60529):
|
Additional condition protection degree:
|
Pollution Degree:
|
Rated surge voltage:
|
Material group (IEC 60664-1):
|
Overvoltage category (EN 60950-1):
|
Mechanical data |
Contour for corrugated hose:
|
Mechanical data | Material data |
Coating housing:
|
Coating contact:
|
Material housing:
|
Material contact carrier:
|
Mechanical data | Mounting data |
Mounting method:
|
Clamping range min.:
|
Clamping range max.:
|
Height:
|
Width:
|
Depth:
|
Environmental characteristics | Climatic |
Operating temperature min.:
|
Operating temperature max.:
|
Important installation notes |
Note on strain relief:
|
Note on bending radius:
|
Classifications |
ECLASS-6.0:
|
ECLASS-6.1:
|
ECLASS-7.0:
|
ECLASS-8.0:
|
ECLASS-9.0:
|
ECLASS-10.1:
|
ECLASS-11.1:
|
ECLASS-12.0:
|
ETIM-5.0:
|
Commercial data |
GTIN:
|
customs tariff number:
|
Packaging unit:
|
Approvals
|
Certificates |
|
|
|
|
|
|
|
|
|
|
|
|
M12P
|
M12P
|
L
|
L
|
Copper
|
Copper alloy
|
|
|
-
|
63 V
|
63 V
|
63 V
|
12 A
|
16 A
|
|
|
1,5 mm²
|
2,5 mm²
|
-
|
14
|
|
|
-
|
Screw terminals SK
|
0,6 Nm
|
-
|
M12 x 1
|
M12 x 1
|
SW17
|
-
|
500
|
100
|
|
|
IP65, IP67
|
IP67
|
inserted, screwed
|
inserted, screwed
|
-
|
3
|
-
|
1,5 kV
|
-
|
II
|
-
|
III
|
|
|
without
|
-
|
|
|
Nickeled
|
-
|
gold plated
|
gold plated
|
Zinc die-casting
|
PA
|
PA
|
PA
|
|
|
inserted, screwed, Shaking protection
|
Schraubgewinde
|
5,8 mm
|
8 mm
|
13,5 mm
|
13 mm
|
53 mm
|
-
|
25 mm
|
-
|
25 mm
|
-
|
|
|
-40 °C
|
-40 °C
|
85 °C
|
85 °C
|
|
|
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
|
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
|
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
|
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
|
|
|
27279221
|
27279221
|
-
|
27260702
|
27440104
|
27440102
|
27440104
|
27440102
|
27440102
|
27440116
|
27440102
|
27440102
|
27440102
|
27440102
|
27440116
|
27440116
|
EC001855
|
EC002635
|
|
|
4048879682558
|
4048879786560
|
85366990
|
85366990
|
1
|
1
|
|
|
|
|
|
|
|
|
|
|
|