Hebt u vragen over onze producten? Onze experts helpen u graag verder! Bel ons op +32 (0)380 868 81

Producten vergelijken

 Doorsturen
Artikel
Technische data
Cable length:
Side 1
Tightening torque:
Family construction form:
Thread:
Degree of protection (EN IEC 60529):
Side 2
Tightening torque:
Family construction form:
Thread:
Width across flats:
Degree of protection (EN IEC 60529):
Electrical data | Supply
Operating voltage DC:
Operating voltage DC min.:
Operating voltage DC max.:
Current operating per contact max.:
Device protection | Electrical
Additional condition protection degree:
Pollution Degree:
Rated surge voltage:
Mechanical data | Material data
Color housing:
Material housing:
Mechanical data | Mounting data
Mounting method:
Environmental characteristics | Climatic
Operating temperature min.:
Operating temperature max.:
Additional condition temperature range:
Important installation notes
Note on strain relief:
Note on bending radius:
Conformity
Product standard:
Cable data
General data | Cable
Cable identification:
Cable Type:
Jacket Color:
Type of Certificate:
Structure | Cable
Amount stranding:
Stranding:
Filler:
wire arrangement:
Mechanical data | Cable
Traversing distance (C-track):
Cable weigth:
Material jacket:
Shore hardness jacket:
Freedom from ingredients (jacket):
Outer-diameter (jacket):
Tolerance outer diameter (sheath):
Material wire insulation:
Amount wires:
Outer diameter insulation :
Outer diameter tolerance core insulation:
Shore hardness wire insulation:
Ingredient freeness wire insulation:
Amount strands (wire):
Diameter of single wires:
Conductor crosssection (wire):
Material conductor wire:
Conductor type (wire):
Electrical data | Cable
Nominal voltage AC max.:
Current load capacity (standard):
Current load capacity min. wire:
Electrical resistance line constant wire:
AC withstand voltage (wire - wire):
Power frequency withstand voltage (wire - jacket):
Temperature range | Cable
Min. operating temperature (static):
Max. operating temperature (fixed):
Operating temperature min. (dynamic):
Operating temperature max. (dynamic):
Resistances | Cable
Hydrolysis resistance:
Ozone resistance:
Seewater resistance:
Acid and alkali resistance:
UV resistance:
Flame resistance:
chemical resistance:
Gasoline resistance:
Oil resistance:
Installation | Cable
Bending radius (fixed):
Bending radius (dynamic):
Travel speed (C-track):
No. of torsion cycles:
Torsion stress:
Torsion speed:
Classifications
ECLASS-6.0:
ECLASS-7.0:
ECLASS-8.0:
ECLASS-9.0:
ECLASS-10.1:
ECLASS-11.1:
ECLASS-12.0:
ETIM-5.0:
Commerciële gegevens
GTIN:
Verpakkingseenheid:
Douane tarief nummer:
Toelatingen
Certificates
Certificate
Certificate
Certificate
Certificate
Verplaats product
M12 male 0° A-cod. / MSUD valve plug A-18mm M12 male 0° A-cod. / MSUD valve plug A-18mm
PUR 5x0.34 gy UL/CSA+drag ch. 3m
Gewicht: 0.165 kg
Art.nr. 7000-40921-2350300

Leveringsdatum op aanvraag
Verplaats product
M12 male 0° A-cod. / MSUD valve plug A-18mm M12 male 0° A-cod. / MSUD valve plug A-18mm
PUR 5x0.34 ye UL/CSA+drag ch. 3m
Gewicht: 0.164 kg
Art.nr. 7000-40921-0350300

Leveringsdatum op aanvraag
3 m
3 m
0,4 Nm
0,4 Nm
MSUD
MSUD
M3
M3
IP67
IP67
0,6 Nm
0,6 Nm
M12
M12
M12 x 1
M12 x 1
SW13
SW13
IP67
IP67
24 V
24 V
18 V
18 V
30 V
30 V
4 A
4 A
inserted, screwed
inserted, screwed
3
3
0,8 kV
0,8 kV
black
black
Plastic
Plastic
inserted, screwed
inserted, screwed
-25 °C
-25 °C
85 °C
85 °C
depending on cable quality
depending on cable quality
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces.
DIN EN 61076-2-101 (M12); DIN EN 175301-803 (Ventilstecker)
DIN EN 61076-2-101 (M12); DIN EN 175301-803 (Ventilstecker)
235
035
3
3
gray
yellow
cURus
cURus
1
1
5 wires around Core filler twisted
5 wires around Core filler twisted
yes
yes
brown, black, blue, white, green-yellow
brown, black, blue, white, green-yellow
10 m @ 25 °C | horizontal
10 m @ 25 °C | horizontal
41,8 g/m
41,8 g/m
PUR
PUR
90 ± 5 Shore A
90 ± 5 Shore A
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
4,8 mm
4,8 mm
± 5 %
± 5 %
PP
PP
5
5
1,25 mm
1,25 mm
± 5 %
± 5 %
70 ± 5 Shore D
70 ± 5 Shore D
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
42
42
0,1 mm
0,1 mm
0,34 mm²
0,34 mm²
Stranded copper wire, bare
Stranded copper wire, bare
strand class 6
strand class 6
300 V
300 V
to DIN VDE 0298-4
to DIN VDE 0298-4
4,5 A
4,5 A
57 Ω/km @ 20 °C
57 Ω/km @ 20 °C
2,5 kV @ 60 s
2,5 kV @ 60 s
2,5 kV @ 60 s
2,5 kV @ 60 s
-40 °C
-40 °C
80 °C / 90 °C @ 10000 h Operation
80 °C / 90 °C @ 10000 h Operation
-25 °C
-25 °C
80 °C / 90 °C @ 10000 h Operation
80 °C / 90 °C @ 10000 h Operation
-
-
-
-
-
-
-
-
-
-
IEC 60332-2-2 | UL 1581 § 1090 | UL 1581 § 1100 FT2
UL 1581 § 1100 FT2 | IEC 60332-2-2 | UL 1581 § 1090
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing
Good, application-related testing | DIN EN 60811-404
DIN EN 60811-404 | Good, application-related testing
5 x Outer diameter
5 x Outer diameter
10 x Outer diameter
10 x Outer diameter
10 Mio. @ 25 °C
10 Mio. @ 25 °C
2 Mio.
2 Mio.
± 180 °/m
± 180 °/m
35 cycles/min
35 cycles/min
27279218
27279218
27279218
27279218
27279218
27279218
27060311
27060311
27060312
27060312
27060312
27060312
27060312
27060312
EC001855
EC001855
4048879150651
4048879150910
1
1
85444290
85444290
* excl. BTW, excl. Verzendkosten